Lumbar Puncture 
Conducted by : Dr. Support Team
Surgeon : Dr. Prashant Sathe
Hospital : Meditorch's Virtual Meet
Date : 14-May-2023 11.00 ()
Product enquiry
Please confirm your contact details so that our team can get in touch with you.
  • Please update all mandatory fields marked with *
Close

Patient Details

Benefits of Skill Lab & its importance as per NMC mandate for UG Colleges Components of a Good Skill Lab: content, processes, simulators/trainers, software

General Procedure

Preoperative investigations
  • No Description Available
Preoperative measures
  • No Description Available
Postoperative measures
  • No Description Available
Warning signs in the postoperative period
  • No Description Available
  • Preoperative investigations
  • Preoperative measures
  • Postoperative measures
  • Warning signs in the postoperative period

Equipment tagged in this procedure

Equipment tagged for this procedure

OT Equipment for this Procedure are not uploaded yet.

Anatomy Tags

Anatomy elements for this Surgery are not uploaded yet

General Steps for this Surgery

1.The manometer should be prepared prior to commencing the spinal injection
2.Once skin is sterile, local anaesthetic can be administered
A small amount of lidocaine can be infiltrated into deeper tissues, but care must be taken not to distort local anatomy .
3.The Lumbar Puncture needle should be inserted at an angle that will allow it to pass between the spinous processes
The most common problem encountered by operators is their needle impacting on a bony structure like spinous process. If this happens, Withdraw the needle and adjust the trajectory, gradually proceeding until a “give” is felt on passing through the ligamentum flavum.
4.• The stylet should be in place when the needle insertion commences
5.Once the needle is sufficiently advanced, withdraw the stylet slowly and wait about 5 seconds
To see if CSF emerges. If it does not, replace the stylet and advance the needle another 2 or 3 mm and check again for CSF.
6.Once CSF is obtained, connect the manometer
If pressure is required to be measured .
7.Samples should be taken either using sterile bottles .
8.Aspiration of CSF is not recommended
As it may cause spinal cord injury.
9.The patient can mobilise as soon as it is comfortable to do so.